M8405A Damper Actuator provides three-position control: closed, adjustable mid-position, and open. The Precedent unit is approximately 6.00 inches wider than a SB which may interfere with trailer mounted fresh air exchange doors.Thermo King fresh air exchange option 070026 is also available. carrier container refrigeration thermo king alarm codes for transport refrigeration units april 29th, 2018 - carrier transicold vector 1350 1550 1850 1950 mt units thermo king alarm codes thermo king truck amp trailer unit alarm codes internal controller fault code ' 'electric truck stop carrier transicold alarm codes may 4th, 2018 - below is a This temperature sensor measures real internal air temperature without the influence of internal surface temperature, providing optimum load protection. Thermo King Electrical Parts buy online at wholesale prices anytime 24/7. 05 Description: Check Ambient Temp Sensor Operator . Thermo King Alarm Codes Defined: 00 NO ALARMS EXIST. (Control) Return Air Sensor (Zone) Check (Control) Discharge Air Sensor (Zone) Check Ambient Temp Sensor Check Coolant Temp Sensor Check Engine RPM Sensor Unit Running on Coil Sensor (Zone) High Evaporator Temperature . These monitor air temps that come into and back out of Thermo King units. We have thermoking shows code 4 check control discharge air sensor Code 204 check display discharge air sensor What does - Answered by a verified Technician. 04 Check (Control) Discharge Air Sensor 05 Check Ambient Air Sensor 06 Check Coolant Temp Sensor 07 Check Engine RPM Sensor 08 Unit Running on Coil Sensor 09 High Evaporator Temperature Service Watch sensors include Discharge Air and Return Air Sensors, and can include Spare Sensors. Set the high Discharge Air Temperature Switch at 170-degree centigrade, on the main scale. Please record all alarms that occur to assist technician in resolving issue. ALWAYS CONSULT YOUR COMPANY FOR FINAL DECISIONS. Precedent S-610M Trailer Refrigeration Unit. The Pretrip prompt screen will appear. In most cases, corroded switches cause a drop in battery voltage. 3 Way Valve Refrigeration System for Thermo King Refrigeration units. long or they may interfere with the back of the control box and engine. Thermo King - Byron Center, MI. Coolant Temperature Sensor: 7. wayne Thermo king code 86 high pressure sensor. We had trouble with High discharge pressure the belt was loose. FAQ; Webinar; . . 2. the Thermo King Logo key for at least 3 seconds. Support small. Truck, trailer, CR, DAS, DSR: 05: ok: Check Ambient Temp Sensor: . It indicates there is a low battery voltage in your Thermo King reefer. Coolant Temperature Sensor 7. DAC (Discharge air control) Kit Key Features. I have a 2004 Thermo SB 190. 03 Check (Control) Return Air Sensor (Zone) Manually monitor temperature. Press the Enter key to start a Pretrip test. Control Discharge Air Sensor: 5. 06 CHECK COOLANT TEMP SENSOR. the high discharge pressure alert is gone. Add oil to the test bottle up to the line on the neck.Replace. High Discharge Pressure During an evaporator defrost cycle, . THERMO KING TK 40933-8-CH (Rev 11 Final1 03-08-12) COLOR CODE DEFINITIONS OK TO RUN CHECK AS SPECIFIED TAKE IMMEDIATE ACTION THESE ARE SUGGESTIONS ONLY. Thermo king code 26 repair This is a listing of all current truck, trailer, CR, DAS and DSR alarm codes. Join Date Oct 2001 Location Nottingham UK Posts 5,557 Rep Power 49 Harmony III Zone Control Panel Discharge Air Sensor (DAS) A discharge air temperature sensor (88K38) monitors the supply air. Precedent takes everything we've learned since we . Sensor Shutdown 13. On multi-temp units, the zone will be identified. M7415 Damper Actuator provides modulating control of economizer dampers from a thermistor mixed-air or discharge sensor to maintain 56F (13C) air temperature. Shooting codes 13-11-2 6 4 I replaced the discharge and return sensors about a year ago I have unplug the read more. Alarm codes with parenthesis (XX) may exist with alarm code 84 and may clear automatically. 05 CHECK AMIBENT TEMP SENSOR. This is the easiest item on the list. Report alarm at end of day. The Precedent platform represents the very latest in transport refrigeration technology, but it's backed by something that can only be built up slowly over time: Thermo King peace-of-mind. . 0 No Alarms Exist 2 Evaporator Coil Sensor 3 Control Return Air Sensor 4 Control Discharge Air Sensor 5 Ambient Air 6 Coolant Temp Sensor 7 Engine RPM Sensor 9 High Evaporator Temperature 10 High Discharge Pressure 11 Unit Controlling on Alternate Sensor 12 Sensor or Digital Input Shutdown 13 Sensor Check . Evaporator Coil Sensor 3. Graded Sensor for Thermo King 400974 40-974 40-871 Air Temp Temperature 40974 Direct Replacement (Plug and Play) For ALL Thermo King Reefer Units TRUST The High Quality of ARCTICO Transport Refrigeration Parts Additional Details Small Business This product is from a small business brand. Fast reacting. Hi there on my thermo king reefer , it show check fuel level sensor . An incorrectly positioned Discharge Air Sensor can cause an incorrect Temperature Differential reading (see SI01 Temperature Differential on page 141). Air Temperature Sensors function as primary and/or secondary sensors in electronic control systems. I have cleared the high discharge pressure sensor like you said but it comes back. Toll Free: 1-800-968-9378 Phone: (616) 878-4900. valtuutettuun Thermo King huoltoon. Description: Check (Control) Discharge Air Sensor (Zone) Operator Action: Manually monitor temperature. Report alarm at end of day. Run a pretrip. Ambient Air Sensor 6. Bottle must be 3/4 full to use or oil can. Report alarm at end of day. The S-610M, which is part of the Precedent multi-temp reefer platform from Thermo King, takes the technology that has made Precedent the premier transport refrigeration platform in the industry and optimizes it for food distribution. Thermo King Refrigeration Repair Manu Truck, trailer, CR, DAS, DSR 04 check Check (Control) Discharge Air Sensor (Zone) Manually monitor temperature. 109 Check High Discharge Pressure Sensor Replaced by Alarm Code 86 110 Check Suction Line Sol Circuit (Zone) If unit/zone is shut down repair immediately. A method of operating a refrigeration system having a discharge port that guides conditioned air from the system to a conditioned space and a return port that guides air from the conditioned space back to the system. A discharge air temperature sensor 584 samples the air temperature of the discharge air. Check (Control) Discharge Air Sensor (Zone) Manually monitor temperature. Control's Discharge air but note no control of return air; Reduces risk of fresh products being damaged by frost . Thermo King units have two main categories of these air temperature sensors which we describe as either Service Watch or Cargo Watch sensors. Please record all alarms that occur to assist the technician in resolving an issue. pump service port or filter port and draw an oil sample into a. clear container for inspection. Thermo King Corp. On multi-temp units, the zone will be identified. position control of economizer systems on HVAC equipment. 04 Check (Control) Discharge Air Sensor Manually monitor temperature. This manual was written to assist with the installation of the Thermo King SB-130, SB-230 and SB-330 Single Temperaturerefrigeration systems onto trailers specifically designed and built for refrigerated applications. Solid state components not affected by dust or dirt. Protrudes a Minimum of 1.0 in. Report alarm at end of day. Engine RPM Sensor 9. Temperature control device and method for its operation US6910341B2 (en) 2003-09-26: 2005-06-28: Thermo King Corporation: . Truck, trailer, CR, DAS, DSR 03 check Check (Control) Return Air Sensor (Zone) Manually monitor temperature. High Evaporator Temperature: 10. Control the steady temperature 170 degrees centigrade of an oil bath, now close contact of a switch. . Control Discharge Air Sensor 5. . Thermo King Alarm Codes - North America This is a listing of all current truck, trailer, CR, DAS and DSR alarm codes. Shooting codes 13-11-2 6 4 I. I have a 2004 Thermo King SB 190. Ambient Air Sensor 6. THERMO KING TRUCK, TRAILER, CR, DAS, AND DSR ALARM CODES. We use cookies to give you the best possible experience on our website. Learn more Specifications for this item Hey I'm having the same issue with my trailer. This electronic sensor's probe is inserted into the discharge air plenum to gather air temperature data for the zone control panel. 1. Figure 1. (25.4 mm) Figure 2: Discharge Air Sensor Position. The design of the in-cab controller lets the voltage go through the on/off switches before the in-cab controller. 05 Description: Check Ambient Temp Sensor Operator Action . Use an access valve (TK 204-625) on the compressor oil. Report alarm at end of day. Contents hide 1 THERMO-KING Temperature and Humidity Sensor Kit 2 Installation Instructions Wireless Sensors 2.1 Kit Contents 2.2 Temperature and Humidity Sensor Kit (401672) 2.3 Door Sensor Kit with Magnet (401674) 3 Important Information 4 Installation Best Practices 5 Wireless Sensor Activation using TK Technician Application 6 Mounting Locations for Temperature/Humidity Sensor 7 . Coolant Temperature Sensor 7. Its a sb-210. Control Return Air Sensor 4. On a restaurant make up unit a discharge air sensors is used to temper the supply air. TB-37-40-980 DISPLAY STATUS LIGHT SB UNITS . HEAT/DEFROST CYCLE High Quality Products MCP Corporation sells high quality spare parts for Thermo King and Carrier which are the most popular transport refrigeration brands. Aluminium Fuel Tank; UltraSonic Fuel Sensor; Service Kit; Fuel Primer Kit; Top Freeze Protect. What it does with that information is more relevent. the cover and shake. Alarm codes with parenthesis (XX) may exist with alarm code 84 and may clear automatically. Mounts on duct or plenum surface with integral mounting flange, or in a 2 x 4 in. High Evaporator Temperature 10. 4. The C7835A1009 Discharge Air Temperature Sensor (DATS) is a duct-mounted temperature probe that provides capacity control of heating and cooling equipment. Sensor Check 15. On multi-temp units, the zone will be identified. . 2. Glow Plug Check/Intake Air Heater 17. 04 CHECK DISCHARGE AIR SENSOR. 02 CHECK EVAPORATOR COIL SENSOR. . Ultimately it senses discharge air. Durable Items MCP Parts is tested numbers of times and they can work long years without any trouble. Tighten battery terminals then open control box.Check for 12 volts at board if it has 12 volts and led light in center of board isn't flashing then board is bad. 1. 4. These units mount on the front of the trailer with the evaporator extending through an opening in the front wall. Otherwise, report alarm . 01 MICROPROCESSOR POWER UP RESET. Engine RPM Sensor 9. See . High Evaporator Temperature 10. Mounted in the supply air duct, the DATS senses the delivered air temperature and cuts off the heating or cooling when the delivered air . 00 2 3 4 5 6 7 8 (09) Code 61 has a yellow status, which needs checking as specified. . 2. Figure 2 shows the kit; see figure 6 (Page 7) for location of the probe. Thermo King Alarm Code 10: High Discharge Pressure. To complete an oil acid test: 1. THIS IS A NON-OEM/AFTERMARKET PART HEATER ELECTRIC AIR Our Price: $150.00 . depends on what application. Report alarm at end of day. As mentioned it can be used as a limit switch if it falls or exceeds predetermined temperatures. Three major components for review are: 1) pulp temperatures of the produce at origin and at time of loading, in comparison to the pulp temperatures reflected at destination on the government inspection, 2) the portable temperature recording device placed inside the trailer at shipping point and 3) the carrier's download of the smart reefer unit. (616) 878-4900 Detroit (313) 532-3006 TK Alarm Codes Services Back Service Programs Mobile Truck Service Warranty Information Operation Support Thermo King Alarm Codes FAQs Parts Back Thermo King Carrier RedDot ESPAR Tubes n' Hoses Request a Part Vehicle Type Back Semi-Trailers Truck Bodies Vans Sleeper - APU Cargo, Specialty Vehicles, & Trailers no alarms exist microprocessor power up reset check evaporator coil sensor check (control) return air sensor check (control) discharge air sensor check ambient temp sensor check. THERMO KING TRUCK, TRAILER, CR, DAS, DSR ALARM CODES . Open up the lower and upper front doors and check for missing or broken belts. %100 Compatibility Software License; Recover Refrigerant; Revision History; Control System Notes; How . On multi-temp units, the zone will be identified. Asset Library; Publications (XEROX) Search SDS Sheets; TK Dealer Portal; Help. Report alarm at end of day. Thermo King Alarm Codes This is a listing of all current truck, trailer, CR, DAS and DSR alarm codes. Efficient, reliable and high performance temperature control requires impeccable accuracy. Ambient Air Sensor: 6. Engine RPM Sensor: 9. Description: Check (Control) Discharge Air Sensor (Zone) Operator Action: Manually monitor temperature. Compared to traditional wall mounted sensors the difference in measured temperature is up to 7C. 6,062 satisfied customers. Title: Thermo King Code Discharge Air Sensor Location Keywords: Thermo King Code Discharge Air Sensor Location Created Date: 11/3/2014 8:55:21 PM About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features Press Copyright Contact us Creators . Thermo King Alarm Codes For the following units: SB-III 30 SR+, SB-III 30 SR TCI-2, Super II 30 SR+ Thermoguard P IV, Super II SR TCI-2 Thermoguard . Engine . A graded sensor for the discharge and return of the air Thermo King genuine part Manufactured by Thermo King Built to original factory specifications Product Warranty: For detailed information please refer to our Warranty policy . THIS IS A NON-OEM/AFTERMARKET PART SENSOR TEMP UNGRADED Our Price: $50.00 . Thermo king codes 63 This is a listing of all current truck, trailer, CR, DAS and DSR alarm codes. An incorrect Temperature Differential reading will cause operational problems. 11 UNIT CONTROLLING ON ALTERNATE SENSOR 12 SENSOR OR DIGTAL INPUT SHUTDOWN 13 SENSOR CHECK 14 DEFROSAT TERMINATE BY TIME 15 CHECK GLOW PLUGS OR INTAKE AIR HEATER 16 MANUAL START NOT COMPLETED 17 ENGINE FAILED TO CRANK 18 HIGH ENGINE COOLANT TEMPERATURE 19 LOW ENGINE OIL PRESSURE 20 ENGINE ( VAPOR MOTOR CR) FAILED TO START 21 COOLING CYCLE CHECK This shutdown alarm code can be difficult to troubleshoot. Air Purification Solutions Toolkit; Precedent Refresh Launch Kit; Asset Library. But will run for awhile then it does it again. Thermo King Alarm Codes Fix Details Category: Thermoking Tamir ve Bakm Published on 11 February 2012 Written by Super User Hits: 18302 . Metro Detroit. Here are a few common tips to make the process a little easier: Check for broken fan belts. Durable Items MCP Parts is tested numbers of times and they can work long years without any trouble. Also the condensor was dirty so we cleaned that. junction box. Report alarm at end of day. . Unit Controlling on Alternate Sensor 12. Aftermarket Thermo King Pressure Sensor 42-2827 42-1309 Transducer Discharge 500 PSI / 4-Wire Part no: 42-2827 42-1309 Application: Thermo King TS / SB Range MCP parts are used extensively in America, Europe and most of Asian countries now. Trailer Edition Precedent S-750i Control System i Preface For None; ii Introduction. No settings or calibration required. See "Mounting Hardware Requirements" on page 12. The C-600 offers outstanding efficiency and reliability paired with superior temperature control. Control Discharge Air Sensor 5. . Rugged aluminum insertion probe. Thermo King Precedent C-600, S-600 and S-700 are one piece, self-contained, diesel powered, air cooling/heating units operating under the control of the SMART REEFER 4 (SR-4) programmable microprocessor controller. See "Evaporator 07 CHECK ENGINE RPM SENSOR. AIA Temperature Sensor; Energy Curtain; Top Freeze Protect; Fuel Management . MCP Corporation sells high quality spare parts for Thermo King and Carrier which are the most popular transport refrigeration brands. 955 76th St. SW Byron Center, MI 49315. High Discharge Pressure 11. It is used only with Honeywell networked zoning. The method comprises providing a first control algorithm and second control algorithm for controlling the system. 03 CHECK RETURN AIR SENSOR. I checked battery terminals 12 volts at the board and green light flashing. The CARB Evergreen certification of the S-610M means no DPF .